RE: Touch screen RIIC issue

Do you have more than 1 pin configured to be SCL? See section 20.6 of the HW manual (Peripheral select settings for each product). Also, in the same section, " select the functional pins having the...

View Article


RE: Touch screen RIIC issue

OK.  Thanks.  I did have more than one pin assigned to SCL.  SSP pin configurator assigned Port 2 pin 04, then in my code I assigned Port 4 pin 7.I changed my code as follows:In my code first I...

View Article


RE: Touch screen RIIC issue

More information:I went back to SSP and defined RIIC channel 0 using only suffix A pins.Then I removed my code to change pins to mix the Suffixes.  Now I do not have SDA actually connected ...Upon...

View Article

RE: Touch screen RIIC issue

Steve-I should check on the Muxing of A and B signals to make sure it is supported in SSP- I know it is in hardware, but maybe there is a software limitation I don;t know about. Look for an update this...

View Article

RE: Touch screen RIIC issue

Hello Warren:I have confirmed in code that I re-assign SCL0 pin after SSP has called this function:ssp_err_g_sf_touch_panel_i2c = g_sf_touch_panel_i2c.p_api->open (g_sf_touch_panel_i2c.p_ctrl,...

View Article


Touch screen RIIC issue

I am trying to get the touch screen framework working on my custom PCB.  I have tried to set up the framework and drivers in the configurator but so far I am not getting the I2C to work at all.I have...

View Article

RE: Real Time Clock Demo application code

Hi Warren,Ok, got it to compile in the E2.  Cant seem to find the documentation.  Where specifically should it have been created?  Is it pdf's?Also fyi this demo I could not get to work and compile...

View Article

RE: Real Time Clock Demo application code

Matt-The pdf doc should be located below your install directory: <Install>/Synergy/SSP_Documentation folder. If you want to search for it on your system it is called...

View Article


RE: Real Time Clock Demo application code

Ok, there it is.  Thank you Warren!!!!Matt

View Article


RE: Setting MAC Address

Nate-Do you mean during configuration as a static MAC address?

View Article

RE: Web Server example

Hi Tim,I met exactly the same issue with you. It's maybe a HW issue of DK-S7G2. I tried another DK-S7G2 board and it works normally. If you don't have any other board, you can try to use the Eth0...

View Article

RE: Keymatrix Switch Example

Hi KAROL,I  have checked the pin setup and its okay. When I call the open API  it directly jump on the callback function. The interrupt had enabled at the initialization. But if interrupt  is enabled...

View Article

RE: gx_prompt_text_set not updating the value

Hi karol,1)I am not handling any events related to created prompt.I have just created the prompt using guix, and trying to update the prompt based on prompt id continuosly using the...

View Article


RE: gx_prompt_text_set not updating the value

Hi karol,One more info.I dont want to handle any of the events.My requirement is, i just want to update a string continuously on the screen, without waiting for any events.Please help me out!!Regards,

View Article

RE: gx_prompt_text_set not updating the value

Hello Nandan,I meant that you should provide a default event handler for unhandled cases ONLY when you already have an event handler function. Otherwise GUIX should use the default function.Are you...

View Article


RE: Setting MAC Address

MAC address is configured inside properties for sf_el_nx (NetX Port ETHER) module.Regards

View Article

Setting MAC Address

How do you set the MAC address in a Synergy Project?

View Article


RE: gx_prompt_text_set not updating the value

Hi karol,Thanks for the reply!!I am using S7G2-SK board.All the API's which i am calling are returning the value 0.One more info, In my project i am not using any touch components and i have only...

View Article

RE: gx_prompt_text_set not updating the value

Hello Nandan,There's also one other thing I seem to have forgotten about. When using GUIX API calls outside of GUIX System Thread context (event and draw handlers), you need to manually force the...

View Article

RE: gx_prompt_text_set not updating the value

Thank you Karol!!Its working with gx_system_dirty_mark and gx_system_canvas_refresh.I had one more query, is it possible to rotate the prompt to 90 degrees??Regards